Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 28.530
Filter
1.
BMC Cardiovasc Disord ; 24(1): 239, 2024 May 07.
Article in English | MEDLINE | ID: mdl-38714966

ABSTRACT

OBJECTIVE: Cerebral malperfusion (CM) is a common comorbidity in acute type A aortic dissection (ATAAD), which is associated with high mortality and poor neurological prognosis. This meta-analysis investigated the surgical strategy of ATAAD patients with CM, aiming to compare the difference in therapeutic effectiveness between the central repair-first and the early reperfusion-first according to clinical outcomes. METHODS: The meta-analysis and systematic review was conducted based on studies sourced from the PubMed, Embase, and Cochrane literature database, in which cases of ATAAD with CM underwent surgical repair were included. Data for baseline characteristics, mortality, survival were extracted, and risk ratio (RR) values and the pooled mortality were calculated. RESULTS: A total of 17 retrospective studies were analyzed, including 1010 cases of ATAAD with CM underwent surgical repair. The pooled early mortality in early reperfusion group was lower (8.1%; CI, 0.02 to 0.168) than that in the central repair group (16.2%; CI, 0.115 to 0.216). The pooled long-term mortality was 7.9% in the early reperfusion cohort and 17.4% the central repair-first cohort, without a statistically significant heterogeneity (I [2] = 51.271%; p = 0.056). The mean time of symptom-onset-to-the-operation-room in all the reports was 8.87 ± 12.3 h. CONCLUSION: This meta-analysis suggested that early reperfusion-first may achieved better outcomes compared to central repair-first in ATAAD patients complicated with CM to some extent. Early operation and early restoration of cerebral perfusion may reduce the occurrence of some neurological complications. TRIAL REGISTRATION: The meta-analysis was registered in the International Prospective Register of Systematic Reviews database (No. CRD CRD42023475629) on Nov. 8th, 2023.


Subject(s)
Aortic Aneurysm , Aortic Dissection , Cerebrovascular Circulation , Humans , Aortic Dissection/surgery , Aortic Dissection/mortality , Aortic Dissection/complications , Aortic Dissection/physiopathology , Aortic Dissection/diagnostic imaging , Treatment Outcome , Risk Factors , Time Factors , Aortic Aneurysm/surgery , Aortic Aneurysm/mortality , Aortic Aneurysm/complications , Aortic Aneurysm/physiopathology , Aortic Aneurysm/diagnostic imaging , Female , Male , Middle Aged , Aged , Acute Disease , Cerebrovascular Disorders/surgery , Cerebrovascular Disorders/etiology , Cerebrovascular Disorders/mortality , Cerebrovascular Disorders/diagnosis , Cerebrovascular Disorders/physiopathology , Adult , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/mortality , Risk Assessment , Reperfusion , Time-to-Treatment
2.
BJS Open ; 8(3)2024 May 08.
Article in English | MEDLINE | ID: mdl-38768283

ABSTRACT

BACKGROUND: Extended aortic repair is considered a key issue for the long-term durability of surgery for DeBakey type 1 aortic dissection. The risk of aortic degeneration may be higher in young patients due to their long life expectancy. The early outcome and durability of aortic surgery in these patients were investigated in the present study. METHODS: The subjects of the present analysis were patients under 60 years old who underwent surgical repair for acute DeBakey type 1 aortic dissection at 18 cardiac surgery centres across Europe between 2005 and 2021. Patients underwent ascending aortic repair or total aortic arch repair using the conventional technique or the frozen elephant trunk technique. The primary outcome was 5-year cumulative incidence of reoperation on the distal aorta. RESULTS: Overall, 915 patients underwent surgical ascending aortic repair and 284 patients underwent surgical total aortic arch repair. The frozen elephant trunk procedure was performed in 128 patients. Among 245 propensity score-matched pairs, total aortic arch repair did not decrease the rate of distal aortic reoperation compared to ascending aortic repair (5-year cumulative incidence, 6.7% versus 6.7%, subdistributional hazard ratio 1.127, 95% c.i. 0.523 to 2.427). Total aortic arch repair increased the incidence of postoperative stroke/global brain ischaemia (25.7% versus 18.4%, P = 0.050) and dialysis (19.6% versus 12.7%, P = 0.003). Five-year mortality was comparable after ascending aortic repair and total aortic arch repair (22.8% versus 27.3%, P = 0.172). CONCLUSIONS: In patients under 60 years old with DeBakey type 1 aortic dissection, total aortic arch replacement compared with ascending aortic repair did not reduce the incidence of distal aortic operations at 5 years. When feasible, ascending aortic repair for DeBakey type 1 aortic dissection is associated with satisfactory early and mid-term outcomes. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT04831073.


Subject(s)
Aorta, Thoracic , Aortic Dissection , Blood Vessel Prosthesis Implantation , Postoperative Complications , Reoperation , Humans , Aortic Dissection/surgery , Aortic Dissection/mortality , Male , Female , Middle Aged , Aorta, Thoracic/surgery , Reoperation/statistics & numerical data , Postoperative Complications/epidemiology , Blood Vessel Prosthesis Implantation/methods , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/mortality , Aortic Aneurysm, Thoracic/surgery , Aortic Aneurysm, Thoracic/mortality , Adult , Retrospective Studies , Treatment Outcome , Europe/epidemiology , Propensity Score
3.
Bratisl Lek Listy ; 125(6): 347-353, 2024.
Article in English | MEDLINE | ID: mdl-38757590

ABSTRACT

PURPOSE: Standard endovascular aortic aneurysm repair (EVAR) is sometimes the only treatment option for patients with hostile aortic neck anatomy, but it carries an increased risk of both early and late procedure-related complications. The aim of this study was to report on single-center experience with the Heli-FX EndoAnchors (Medtronic, Santa Rosa, CA) as an adjunctive procedure to endovascular aneurysm repair (EVAR) for prevention and perioperative treatment of proximal neck complications in patients with hostile neck anatomy.  MATERIALS AND METHODS: A single-centre, retrospective study evaluating 24 consecutive patients treated with EndoAnchors during the index EVAR procedure between November 2018 and August 2021. EndoAnchor implantation was indicated for cases with hostile proximal aortic neck anatomy characterised by the presence of at least one of the following parameters: length of 28 mm, angle of >60°, circumferential thrombus/calcification involving ≥50%, and reverse taper. RESULTS:  Median follow-up period was 22.5 months (IQR 2-31.5 months) with no aneurysm-related death, rupture, or conversion to open surgical repair during the follow-up. The procedural success rate was 100%, with no type Ia endoleak at the completion angiography. A mean of 7 EndoAnchors was used per patient (range 4-12). There were no EndoAnchor fractures and dislocations or stent graft fabric damage due to anchor implants. Twenty-three patients (95.8%) remained free of type Ia endoleak and migration on follow-up imaging. Aneurysm sac regression was observed in 13 patients (54.1%), while in 8 patients (33.3%) the sac remained stable. Sac enlargement was present in 1 patient (4.2%) due to late type Ia endoleak. Two patients were lost to the follow-up immediately after the procedure. Between two groups of patients (sac regression versus failure to regress), the larger initial diameter of the proximal neck was the only significant independent factor associated with a lower possibility of sac regression (p= 0,021). CONCLUSIONS:  The use of EndoAnchors during the index EVAR procedure in cases with challenging aortic neck anatomy with or without perioperative type Ia endoleak was associated with good midterm results and led to sac regression in most of the patients (Tab. 4, Fig. 3, Ref. 31).


Subject(s)
Aortic Aneurysm, Abdominal , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Humans , Endovascular Procedures/methods , Male , Retrospective Studies , Female , Aged , Aortic Aneurysm, Abdominal/surgery , Aortic Aneurysm, Abdominal/diagnostic imaging , Blood Vessel Prosthesis Implantation/methods , Blood Vessel Prosthesis Implantation/instrumentation , Aged, 80 and over , Postoperative Complications/prevention & control , Endoleak/etiology , Endoleak/prevention & control , Treatment Outcome , Blood Vessel Prosthesis , Stents
4.
Zhonghua Yi Xue Za Zhi ; 104(17): 1499-1506, 2024 May 07.
Article in Chinese | MEDLINE | ID: mdl-38706057

ABSTRACT

Objective: To Compare the effects and safety of lumen reshaping after thoracic endovascular aortic repair (TEVAR) for Stanford B type aortic dissection (AD) at different intervention times. Methods: A retrospective analysis was conducted on the clinical data of 189 patients with Stanford type B aortic dissection treated with TEVAR at the Affiliated Hospital of Chengde Medical College from January 2016 to December 2020.Based on the time from onset to surgery, patients were divided into an early intervention group (≤14 days, n=127) and a delayed intervention group (>14 days, n=62).The diameters of the total aorta, true lumen and false lumen at different times and planes (S1 plane: at the bifurcation of the pulmonary artery; S2 plane: at the lower edge of the left atrium; S3 plane: at the upper edge of the celiac trunk) post-surgery were compared between the two groups, and the rate of change in diameters of true and false lumens across these planes was calculated. The patients were followed until December 1st, 2023, and the median follow-up time was 45(40, 49) months. The postoperative complications and survival of the two groups were compared. Results: The early intervention group comprised 86 men and 41 women, with an average age of (58.3±10.7) years. The delayed intervention group included 41 men and 21 women, with an average age of (58.5±9.2) years. Both groups had an operation success rate of 100%. Six months post-surgery, the early intervention group had an expansion rate of the true lumen diameter at planes S2 and S3 of 40.1%(25.5%, 56.1%) and 5.3%(-2.5%, 15.8%), respectively, which was superior to the delayed intervention group's 18.5%(10.6%, 39.8%) and 1.0%(-8.2%, 9.6%) (both P<0.05).The early intervention group had a reduction rate of the false lumen diameter at planes S1, S2, and S3 of -56.2%(-61.3%, -48.8%), -70.4%(-81.8%, -56.6%), and -5.4%(-17.4%, 0.1%), respectively, better than the delayed intervention group's -44.2%(-53.7%, -38.3%), -49.0%(-57.6%, -35.8%), and -3.1%(-6.7%, 1.8%) (all P<0.05).At plane S1, the true lumen diameter of patients in both groups showed an increasing trend over 36 months post-surgery, while the false lumen diameter showed a decreasing trend (both P<0.05).At plane S2, the true lumen diameter of patients in the early intervention group exhibited an increasing trend over 36 months post-surgery, and the false lumen diameter exhibited a decreasing trend (both P<0.05).At plane S3, the total aortic diameter of patients in the delayed intervention group showed a slight increasing trend over 36 months post-surgery (P<0.05).The overall survival time were 45.0 months (95%CI: 42.9-47.1) for patients in the early intervention group and 46.0 months (95%CI: 43.5-48.5) for those in the delayed intervention group, with no statistically significant difference observed (P>0.05).The incidence rates of complications such as aortic rupture, retrograde Type A dissection, new distal endograft dissection, endoleak, paraplegia, and others showed no statistically significant difference between the two groups (all P>0.05), with no cases of stent migration or deformation observed. Conclusion: Early intervention for Stanford type B aortic dissection provides a better aortic remodeling outcome than delayed intervention, with similar safety.


Subject(s)
Aortic Aneurysm, Thoracic , Aortic Dissection , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Humans , Male , Female , Aortic Dissection/surgery , Middle Aged , Retrospective Studies , Endovascular Procedures/methods , Aortic Aneurysm, Thoracic/surgery , Blood Vessel Prosthesis Implantation/methods , Postoperative Complications , Aorta, Thoracic/surgery , Treatment Outcome , Time Factors , Aged
5.
J Cardiothorac Surg ; 19(1): 276, 2024 May 04.
Article in English | MEDLINE | ID: mdl-38704597

ABSTRACT

BACKGROUND: Conventional graft replacement for a juxtarenal abdominal aortic aneurysm (JRAAA) remains challenging for high-risk patients since it often requires the reconstruction of some visceral arteries. CASE PRESENTATION: A 76-year-old woman was diagnosed with an 87 × 48 mm saccular JRAAA. Open graft replacement was contraindicated because of frailty and a past history of trans-thoracoabdominal esophagectomy. Chimney endovascular aortic repair (ChEVAR) with three chimney endografts was successfully performed without any endoleaks, and each visceral circulation was kept intact. The patient was discharged uneventfully on postoperative day 8. Significant shrinkage of the aneurysmal sac and preservation of flow through each chimney graft were observed on computed tomography 6 months postoperatively, with no significant increase in serum creatinine levels on laboratory testing. CONCLUSIONS: ChEVAR can be a useful surgical option instead of conventional operations, especially for high-risk cases.


Subject(s)
Aortic Aneurysm, Abdominal , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Esophagectomy , Humans , Female , Aged , Aortic Aneurysm, Abdominal/surgery , Endovascular Procedures/methods , Esophagectomy/adverse effects , Esophagectomy/methods , Blood Vessel Prosthesis Implantation/methods , Tomography, X-Ray Computed , Endovascular Aneurysm Repair
7.
Kyobu Geka ; 77(5): 357-360, 2024 May.
Article in Japanese | MEDLINE | ID: mdl-38720604

ABSTRACT

A 52-year-old woman with Marfan syndrome developed Stanford type B aortic dissection and was treated with thoracic endovascular aortic repair. However, 29 months later, she presented with retrograde Stanford type A aortic dissection. We successfully performed aortic arch replacement with the frozen elephant trunk technique and valve-sparing aortic root replacement. The advantages of the frozen elephant trunk technique are that the distal anastomosis can be created without stent-graft resection and the cardiac arrest time is shortened. Therefore, the frozen elephant trunk technique was considered valuable and safe in this potentially lethal situation.


Subject(s)
Aortic Aneurysm, Thoracic , Aortic Dissection , Endovascular Procedures , Marfan Syndrome , Humans , Female , Marfan Syndrome/complications , Marfan Syndrome/surgery , Middle Aged , Aortic Dissection/surgery , Aortic Dissection/etiology , Aortic Dissection/diagnostic imaging , Aortic Aneurysm, Thoracic/surgery , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/etiology , Blood Vessel Prosthesis Implantation , Aorta, Thoracic/surgery , Aorta, Thoracic/diagnostic imaging , Endovascular Aneurysm Repair
8.
Article in English | MEDLINE | ID: mdl-38749718

ABSTRACT

PURPOSE: Achieving a secure anastomosis and complete hemostasis is essential for surgically treating type A acute aortic dissection (TAAAD). This study assessed the clinical feasibility of "tailored stand-up collar (TSC)" technique for constructing the distal stump. METHODS: We enrolled 68 patients who underwent ascending aortic repair for TAAAD. Patients were categorized according to the technique for distal stump construction: conventional (C) group using only a felt strip (32 cases); post-aortotomy (P) group, with a Hydrofit-felt strip attached after aortotomy (18 cases), and TSC group, where a Hydrofit-felt strip attached during cooling (18 cases). Pre-operative characteristics, procedural profiles, and post-operative outcomes were evaluated. RESULTS: The pre-operative characteristics were identical among the groups. The durations of cardiopulmonary bypass, hemostasis, and surgery were significantly shorter in the P and TSC groups. The duration of open distal in the TSC group (21 min) was significantly shorter than the other two groups. Post-operative additional procedures were not required for the TSC group and their post-operative hospital stay was significantly shorter (47.1% of patients were discharged within 2 weeks). CONCLUSION: The TSC technique would be practical because of its high reproducibility in terms of ease of use, shorter anastomotic time, and secure hemostasis.


Subject(s)
Aortic Dissection , Blood Vessel Prosthesis Implantation , Feasibility Studies , Length of Stay , Humans , Aortic Dissection/surgery , Aortic Dissection/diagnostic imaging , Female , Male , Treatment Outcome , Middle Aged , Aged , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/instrumentation , Time Factors , Acute Disease , Retrospective Studies , Operative Time , Aortic Aneurysm/surgery , Aortic Aneurysm/diagnostic imaging , Aortic Aneurysm, Thoracic/surgery , Aortic Aneurysm, Thoracic/diagnostic imaging , Adult , Postoperative Complications/etiology
9.
J Cardiothorac Surg ; 19(1): 170, 2024 Apr 02.
Article in English | MEDLINE | ID: mdl-38566230

ABSTRACT

BACKGROUND: Open repair of thoracoabdominal aortic aneurysm (TAAA) was characterized by significant risk of postoperative mortality and morbidity. The aim of this study was to determine the perioperative predictors of early and long-term mortality in patients undergoing open repair of TAAA. Besides, the postoperative outcomes in patients with open repair of TAAA were described. METHODS: This is a single-center retrospective study, and 146 patients with open repair of TAAA from January 4, 2011, to November 22, 2018 was involved. Categorical variables were analyzed by the Chi-square test or Fisher's exact test, and continuous variables were analyzed by the independent sample t-test and the WilCoxon rank-sum test. Multivariate Logistic regression and Cox regression were applied to identify the predictors of 30-day and long-term mortality, respectively. The Kaplan Meier curves were used to illustrate survival with the Log-rank test. RESULTS: The 30-day mortality was 9.59% (n = 14). Older than 50 years, the intraoperative volume of red blood cell (RBC) and epinephrine use were independently associated with postoperative 30-day mortality in open repair of TAAA. Long-term mortality was 17.12% (n = 25) (median of 3.5 years (IQR = 2-5 years) of follow-up). Prior open thoracoabdominal aortic aneurysm (TAAA) repair, aortic cross-clamping (ACC) time, intraoperative volume of RBC and use of epinephrine were independently correlated with long-term mortality. CONCLUSIONS: Identifying perioperative risk factors of early and long-term mortaliy is crucial for surgeons. Intraoperative volume of RBC and use of epinephrine were predictors of both early and long-term mortality. In addition, patients of advanced age, prior open repair of TAAA and prolonged ACC time should be paid more attention.


Subject(s)
Aortic Aneurysm, Thoracic , Aortic Aneurysm, Thoracoabdominal , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Humans , Aortic Aneurysm, Thoracic/complications , Treatment Outcome , Retrospective Studies , Blood Vessel Prosthesis Implantation/adverse effects , Risk Factors , Epinephrine , Postoperative Complications/etiology , Endovascular Procedures/adverse effects , Risk Assessment
10.
J Cardiovasc Surg (Torino) ; 65(2): 85-98, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38635284

ABSTRACT

Endovascular aortic repair (EVAR) is nowadays the establishment treatment for patients with abdominal aortic aneurysm (AAA) both in elective and urgent setting. Despite the large applicability and satisfactory results, the presence of hostile iliac anatomy affects both technical and clinical success. This narrative review aimed to report the impact of iliac access and related adjunctive procedures in patients undergoing EVAR in elective and non-elective setting. Hostile iliac access can be defined in presence of narrowed, tortuous, calcified, or occluded iliac arteries. These iliac characteristics can be graded by the anatomic severity grade score to quantitatively assess anatomic complexity before undergoing treatment. Literature shows that iliac hostility has an impact on device navigability, insertion and perioperative and postoperative results. Overall, it has been correlated to higher rate of access issues, representing up to 30% of the first published EVAR experience. Recent innovations with low-profile endografts have reduced large-bore sheaths related issues. However, iliac-related complications still represent an issue, and several adjunctive endovascular and surgical strategies are nowadays available to overcome these complications during EVAR. In urgent settings iliac hostility can significantly impact on particular time sensitive procedures. Moreover, in case of severe hostility patients might be written off for EVAR repair might be inapplicable, exposing to higher mortality/morbidity risk in this urgent/emergent setting. In conclusion, an accurate anatomical evaluation of iliac arteries during preoperative planning, materials availability, and skilled preparation to face iliac-related issues are crucial to address these challenges.


Subject(s)
Aortic Aneurysm, Abdominal , Blood Vessel Prosthesis Implantation , Elective Surgical Procedures , Endovascular Procedures , Iliac Artery , Humans , Aortic Aneurysm, Abdominal/surgery , Aortic Aneurysm, Abdominal/diagnostic imaging , Endovascular Procedures/adverse effects , Endovascular Procedures/instrumentation , Iliac Artery/surgery , Iliac Artery/diagnostic imaging , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/instrumentation , Treatment Outcome , Risk Factors , Blood Vessel Prosthesis , Postoperative Complications/etiology
11.
Eur J Cardiothorac Surg ; 65(5)2024 May 03.
Article in English | MEDLINE | ID: mdl-38676575

ABSTRACT

OBJECTIVES: Conventional treatment for type A aortic dissection includes replacement of the ascending aorta with an open distal anastomosis in the hemiarch position. The frozen elephant trunk (FET) is a hybrid technique that extends the repair to the descending thoracic aorta. The goal is to improve resolution of malperfusion syndrome and to induce positive aortic remodelling and reduce the need for reintervention on the downstream aorta. We aim to summarize the data on the short and long-term outcomes of this technique. METHODS: A thorough search of the literature was conducted isolating all articles dealing with aortic remodelling after the use of FET in case of type A acute aortic dissection. Keywords 'aortic dissection', 'frozen elephant trunk', 'aortic remodelling' and 'false lumen thrombosis' were used. Data for type B and chronic aortic dissections were excluded. RESULTS: FET use favourably influences aortic remodelling. The main advantages lie in the exclusion of distal entry tears in either the aortic arch or descending aorta thus restoring antegrade blood flow in the true lumen and inducing false lumen thrombosis. False lumen thrombosis is not only induced at the level of the stent deployment but also lower in the distal descending aorta. Moreover, it offers an adequate landing zone in the mid-descending aorta for second-stage endovascular or open surgical aortic repair, if needed. CONCLUSIONS: FET can be advantageous in the treatment of acute type A aortic dissection dealing with extended aortic pathology.


Subject(s)
Aortic Aneurysm, Thoracic , Aortic Dissection , Blood Vessel Prosthesis Implantation , Humans , Aortic Dissection/surgery , Blood Vessel Prosthesis Implantation/methods , Aortic Aneurysm, Thoracic/surgery , Acute Disease , Blood Vessel Prosthesis , Aorta, Thoracic/surgery , Endovascular Procedures/methods , Stents , Treatment Outcome
12.
J Cardiovasc Surg (Torino) ; 65(2): 124-131, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38635285

ABSTRACT

INTRODUCTION: We performed a systematic review and meta-analysis to assess the existing published evidence regarding the safety and efficacy of the endovascular aortic repair with chimney technique (ch-EVAR) and physician-modified stent-grafts (PMSGs) for the treatment of pararenal aortic aneurysm repair. EVIDENCE ACQUISITION: A systematic search of all relevant studies reported until October 2023 according to the PRISMA (preferred reporting items for systematic reviews and meta-analyses) guidelines was performed. The pooled 30-day mortality, peri- and postoperative complication rates were estimated using fixed or random effect methods. EVIDENCE SYNTHESIS: A total of 679 study titles were identified by the initial search strategy, of which 16 were considered eligible for inclusion in the meta-analysis. A total of 1094 patients (ch-EVAR N.=861 and PMSG N.=233) (90% male) were identified. The pooled 30-day mortality rate was 3.4% for ch-EVAR and 2.6% for PMSG. The major adverse events (MAE) in the early period was 14.7% for ch-EVAR and 18.5% PMSG, respectively. Higher occlusion rate was observed of the chimney stents grafts (8.2%) than the bridging stents (1.4%) during the follow-up period. CONCLUSIONS: Ch-EVAR and physician-modified technology are safe with low 30-day mortality in elective settings for pararenal aortic aneurysms repair. No significant differences were seen between the two surgical methods regarding the early major adverse events rate. However, higher occlusion rate for the chimneys can be expected over time.


Subject(s)
Aortic Aneurysm, Abdominal , Blood Vessel Prosthesis Implantation , Blood Vessel Prosthesis , Endovascular Procedures , Postoperative Complications , Prosthesis Design , Stents , Humans , Endovascular Procedures/adverse effects , Endovascular Procedures/instrumentation , Endovascular Procedures/mortality , Endovascular Procedures/methods , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis Implantation/mortality , Treatment Outcome , Aortic Aneurysm, Abdominal/surgery , Aortic Aneurysm, Abdominal/mortality , Aortic Aneurysm, Abdominal/diagnostic imaging , Postoperative Complications/etiology , Risk Factors , Male , Female , Aged , Time Factors , Risk Assessment , Middle Aged
13.
J Cardiovasc Surg (Torino) ; 65(2): 110-118, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38635286

ABSTRACT

BACKGROUND: The aim of this study was to evaluate the anatomical feasibility of current available fenestrated endografts (FEVAR) and on-label chimney technique (EnChEVAR) in patients with complex abdominal aortic aneurysms (C-AAA). METHODS: Feasibility of EnChEVAR (Endurant II/IIS CE-marked [Medtronic]) and 4 types of FEVAR (Zenith Fenestrated CE-marked, Zenith Fenestrated Low-Profile [LP] custom-made device [CMD] [Cook Medical], Fenestrated Anaconda LoPro90 CMD, Fenestrated Treo CMD [Terumo Aortic]) was assessed according to the manufacturer's instructions for use. Computed tomography angiograms of patients with C-AAA previously included in the Protagoras 2.0 study were retrospectively reviewed. The aortic coverage was ideally planned to involve a maximum of two chimney grafts or fenestrations. RESULTS: Iliac access and aortic neck of 73 C-AAAs were analyzed. The overall feasibility was significantly different between EnChEVAR (33%) and FEVAR (Zenith Fenestrated 15%, Zenith Fenestrated LP 15%, Fenestrated Anaconda LoPro90 45%, Fenestrated Treo 48%). The iliac access feasibility was significantly lower for Zenith Fenestrated with standard profile compared to all other grafts. The aortic neck feasibility was significantly higher for EnChEVAR and both Terumo Aortic fenestrated stent grafts, compared to both Cook Medical grafts. The treatment using any of the three current available fenestrated grafts with lower profile (Zenith Fenestrated LP, Fenestrated Anaconda LoPro90, Fenestrated Treo) would have been feasible in 71% of the cases. CONCLUSIONS: Most of the patients treated by ChEVAR would have not been treated by first generation fenestrated stent graft. The current available fenestrated endografts, with lower profile and suitable also for angulated necks, increase the anatomical feasibility.


Subject(s)
Aortic Aneurysm, Abdominal , Blood Vessel Prosthesis Implantation , Blood Vessel Prosthesis , Computed Tomography Angiography , Endovascular Procedures , Feasibility Studies , Prosthesis Design , Stents , Humans , Aortic Aneurysm, Abdominal/surgery , Aortic Aneurysm, Abdominal/diagnostic imaging , Endovascular Procedures/instrumentation , Endovascular Procedures/adverse effects , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis Implantation/adverse effects , Retrospective Studies , Female , Male , Aged , Treatment Outcome , Aged, 80 and over , Contrast Media , Aortography
15.
J Cardiovasc Surg (Torino) ; 65(2): 106-109, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38635287

ABSTRACT

BACKGROUND: The aim of this study was to evaluate the early results of the CE-marked standardized device combination consisting of Endurant and the Radiant chimney graft (En-ChEVAR) for the treatment of juxtarenal aortic aneurysms. METHODS: We analyzed multicentric non-industry sponsored case series evaluating the EnChEVAR technique for patients treated between December 2022 and February 2024. Clinical, perioperative procedure-related and radiological data were collected. The primary outcome measure was the freedom of a type Ia gutter-related endoleak at postoperative computed tomography angiography (CTA). Secondary outcome measures included early type Ia endoleak-related reinterventions, target vessel complications including dissection or loss of target vessel, major adverse events, and mortality. Continuous variables were presented as median (interquartile range [IQR]) and categorical variables as count and percentage. RESULTS: Ten patients were included in the present study. Eight (80%) were males, in nine cases a single chimney was implanted, and the other one was a double chimney graft placement. The treated aneurysms had an infrarenal neck length of 3.4 (1.2) mm. The rate of main body oversizing was 30%. The new neck length after chimney graft placement was 18 (3) mm. The median procedural time was 130 (17) mm, contrast medium use was 109 (26) mL, radiation time was 45 (12) min. The technical success was 100%. No type Ia endoleak was detected at the postoperative CTA. There were no target vessel issues. No major adverse events or death were observed. CONCLUSIONS: First reported cohort of patients treated with EnChEVAR demonstrated reproducible clinical and procedural outcomes within the 3 vascular centers with total exclusion of the aneurysms, patent renal arteries, and no evidence of gutter-related type IA endoleak. Further evidence with larger sample size of treated patients and longer follow-up are needed.


Subject(s)
Aortic Aneurysm, Abdominal , Blood Vessel Prosthesis Implantation , Blood Vessel Prosthesis , Endoleak , Endovascular Procedures , Prosthesis Design , Registries , Humans , Male , Female , Endovascular Procedures/adverse effects , Endovascular Procedures/instrumentation , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis Implantation/mortality , Aged , Aortic Aneurysm, Abdominal/surgery , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/mortality , Endoleak/etiology , Time Factors , Treatment Outcome , Aged, 80 and over , Stents , Retrospective Studies , Risk Factors , Product Labeling , Endovascular Aneurysm Repair
16.
ACS Biomater Sci Eng ; 10(5): 3120-3135, 2024 May 13.
Article in English | MEDLINE | ID: mdl-38624019

ABSTRACT

The production of small-diameter artificial vascular grafts continues to encounter numerous challenges, with concerns regarding the degradation rate and endothelialization being particularly critical. In this study, porous PCL scaffolds were prepared, and PCL vascular grafts were fabricated by 3D bioprinting of collagen materials containing adipose-derived mesenchymal stem cells (ADSCs) on the internal wall of the porous PCL scaffold. The PCL vascular grafts were then implanted in the abdominal aorta of Rhesus monkeys for up to 640 days to analyze the degradation of the scaffolds and regeneration of the aorta. Changes in surface morphology, mechanical properties, crystallization property, and molecular weight of porous PCL revealed a similar degradation process of PCL in PBS at pH 7.4 containing Thermomyces lanuginosus lipase and in situ in the abdominal aorta of rhesus monkeys. The contrast of in vitro and in vivo degradation provided valuable reference data for predicting in vivo degradation based on in vitro enzymatic degradation of PCL for further optimization of PCL vascular graft fabrication. Histological analysis through hematoxylin and eosin (HE) staining and fluorescence immunostaining demonstrated that the PCL vascular grafts successfully induced vascular regeneration in the abdominal aorta over the 640-day period. These findings provided valuable insights into the regeneration processes of the implanted vascular grafts. Overall, this study highlights the significant potential of PCL vascular grafts for the regeneration of small-diameter blood vessels.


Subject(s)
Aorta, Abdominal , Blood Vessel Prosthesis , Collagen , Macaca mulatta , Mesenchymal Stem Cells , Polyesters , Tissue Scaffolds , Animals , Polyesters/chemistry , Collagen/chemistry , Mesenchymal Stem Cells/cytology , Mesenchymal Stem Cells/metabolism , Tissue Scaffolds/chemistry , Adipose Tissue/cytology , Blood Vessel Prosthesis Implantation
17.
Ann Card Anaesth ; 27(2): 162-164, 2024 Apr 01.
Article in English | MEDLINE | ID: mdl-38607881

ABSTRACT

ABSTRACT: We report a case of simultaneous transcatheter aortic valve replacement and endovascular aneurysm repair. Our aim was to advocate the role of local and regional anesthesia as a key contributor in maintaining hemodynamic stability and avoiding abrupt blood pressure change. Endovascular combined procedures are gaining popularity for their numerous advantages. Nevertheless, they carry significant risks for their hemodynamic implications. It is imperative to acknowledge the modifications occurring after each correction and act accordingly. Different anesthesia approaches can dramatically influence hemodynamics; among all, we found local and regional anesthesia would better serve this objective.


Subject(s)
Anesthesia, Conduction , Anesthetics , Aortic Aneurysm, Abdominal , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Transcatheter Aortic Valve Replacement , Humans , Aortic Aneurysm, Abdominal/surgery
18.
J Cardiothorac Surg ; 19(1): 239, 2024 Apr 17.
Article in English | MEDLINE | ID: mdl-38632653

ABSTRACT

OBJECTIVES: Aortic pathologies often present with elevated inflammatory biomarkers due to the nature of the disease. Open aortic surgery causes significant trauma to the body due to often mandatory ischemic periods, long cardiopulmonary bypass times and polytransfusion. We aim to determine postoperative trends on inflammation biomarkers for different aortic pathologies and type of surgery in different segments of the aorta. METHODS: Retrospective review of prospectively collected data of 193 consecutive patients who underwent aortic surgery in our centre between 2017 and 2021, grouped according to the type of aortic intervention: (1) Type A aortic dissection (AD) repair with ascending aorta/hemiarch replacement, (2) Aortic root replacement (ARR), (3) Aortic arch + Frozen elephant trunk (FET), (4) Descending thoracic aorta (DTA)/Thoraco-Abdominal aortic repair (TAA). Primary outcomes were daily values of white blood cells (WBC) and C-Reactive Protein (CRP) during the first 15 postoperative days. RESULTS: All groups had a similar inflammatory peak in the first 2-4 days (WBC 12-15 × 109 c/L). AD and FET groups show similar trends with WBC and CRP peaks on days 2 and 10. The ARR group didn't experience the 2nd peak as most patients were already discharged. DTA/TAA patients experienced a more prolonged inflammatory response, reaching a plateau by day 5-10. AD group shows the highest WBC levels and the DTA/TAAA group the highest CRP levels. CRP levels remain elevated (100-200 mg/L) in all groups after 15 postoperative days. CONCLUSIONS: Inflammatory biomarkers show different postoperative trends depending on the clinical presentation and complexity of the aortic procedure performed. Further understanding of the inflammatory response to different aortic pathologies and surgical procedures will permit reduction on the liberal use of antibiotics that this cohort of patients are usually exposed to. An earlier version of the data included in this manuscript was presented as Oral Abstract in the UK Society of Cardiothoracic Surgery Annual meeting in 2021.


Subject(s)
Aortic Aneurysm, Thoracic , Blood Vessel Prosthesis Implantation , Humans , Blood Vessel Prosthesis Implantation/methods , Aorta/surgery , Aorta, Thoracic/surgery , Retrospective Studies , Inflammation , Biomarkers , Aortic Aneurysm, Thoracic/surgery , Treatment Outcome , Blood Vessel Prosthesis
19.
Catheter Cardiovasc Interv ; 103(6): 1074-1077, 2024 May.
Article in English | MEDLINE | ID: mdl-38577923

ABSTRACT

Transcatheter aortic valve implantation (TAVI) has traditionally been indicated for the treatment of aortic stenosis. However, in this case report, we describe a successful TAVI procedure in a 46-year-old male patient who had previously undergone David aortic valve-sparing aortic root replacement for type 1 aortic dissection. The patient presented with aortic valve insufficiency 4 years after the initial surgery and was subsequently treated with a 34 mm Medtronic CoreValve Evolut R prosthesis via TAVI. This case highlights the feasibility of TAVI as a viable treatment option for postoperative aortic valve insufficiency in patients with prior ascending aortic or aortic arch surgery.


Subject(s)
Aortic Dissection , Aortic Valve Insufficiency , Aortic Valve , Blood Vessel Prosthesis Implantation , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Male , Aortic Dissection/surgery , Aortic Dissection/diagnostic imaging , Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve Insufficiency/etiology , Aortic Valve Insufficiency/surgery , Aortic Valve Insufficiency/physiopathology , Middle Aged , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/instrumentation , Treatment Outcome , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis Implantation/adverse effects , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Prosthesis Design , Blood Vessel Prosthesis , Aortic Aneurysm, Thoracic/surgery , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm/surgery , Aortic Aneurysm/diagnostic imaging , Aortography
20.
Medicine (Baltimore) ; 103(14): e37731, 2024 Apr 05.
Article in English | MEDLINE | ID: mdl-38579061

ABSTRACT

RATIONALE: A hostile iliac access route is an important consideration when enforcing endovascular aneurysm repair (EVAR) for abdominal aortic aneurysms (AAA). Herein, we report a case of AAA with unilateral external iliac artery occlusion, for which bifurcated EVAR was successfully performed using a single femoral and brachial artery access. PATIENT CONCERNS: A 76-year-old man who had undergone surgery for lung cancer 4.5 years prior was diagnosed AAA by computed tomography (CT). DIAGNOSIS: Two and a half years before presentation, CT revealed an infrarenal 48 mm AAA, which had enlarged to 57 mm by 2 months preoperatively. CT identified occlusion from the right external iliac artery to the right common femoral artery, with no observed ischemic symptoms in his right leg. The right external iliac artery, occluded and atrophied, had a 1 to 2 mm diameter. INTERVENTION: Surgery was commenced with the selection of a Zenith endovascular graft (Cook Medical) with an extended body length. Two Gore Viabahn VBX balloon expandable endoprosthesis (VBX; W.L. Gore & Associate) were delivered from the right axilla as the contralateral leg. OUTCOMES: CT scan on the 2nd day after surgery revealed no endoleaks. LESSONS: While the long-term results remain uncertain, this method may serve as an option for EVAR in patients with unilateral external iliac artery occlusion.


Subject(s)
Aortic Aneurysm, Abdominal , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Iliac Aneurysm , Male , Humans , Aged , Aortic Aneurysm, Abdominal/complications , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/surgery , Blood Vessel Prosthesis , Blood Vessel Prosthesis Implantation/methods , Iliac Artery/diagnostic imaging , Iliac Artery/surgery , Axilla/surgery , Leg/surgery , Endovascular Procedures/methods , Stents , Treatment Outcome , Iliac Aneurysm/surgery
SELECTION OF CITATIONS
SEARCH DETAIL
...